Electrical Specifications

Test Conditions at 25° C -Typical D D2 D21
D* (Pk.,600,1) x 1011 1.5 2.5 2.8
Peak Wavelength Response - Microns 2.5 2.6 2.7
Time Constant - Milliseconds Typ 800 1200 1800
Resistance - Megohms 2-10 2-12 2-1 5
Operating Temperature - °C -25 -35 -50
Cooler Power - Volts DC/Amps 1V/2A .8V/1.3A 1.9V/1.4A

Active Area Specifications

Code
Number
Active Area Bias Voltage Typical VW-1X15 Responsivity Package
Size
Inches mm Typical -25 -35 -50
1 .040 1 50 .9-1x106 1-2x106 1.5-2.5x106 TO-5-37-8-66
2 .080 2 100 6-9x105 .6-1x106 0.6-1.2x106 TO-5-37-8-66
3 .120 3 150 4-6x105 4-6x105 4-6x105 TO-5-37-8-66
5 .200 5 250 2-4x105 NA 2-4105 TO-8-66
10 .400 10 500 1-2x105 NA NA TO-3

Mechanical Specifications

Lead Sulfide

 