Select the proper lead selenide electrical type (F; FM) and match it with the proper mechanical and package code number. Example: FM-1-5, FM-5-8. The active areas listed are considered standard sizes. Special size plate cells are available upon request.
Electrical Specifications
Test Conditions at 23°C - Typical | F & FM | FA & FAM | FS & FSM |
---|---|---|---|
D* (Pk.,1000,1) x 1010 | .1 - .3 | .4 - .5 | .6-1.5 |
Peak Wavelength Response - Microns Typ | 3.8 | 3.8 | 3.8 |
Time Constant - Microseconds | 2 - 5 | 2 - 5 | 2 - 5 |
Resistance - Megohms | .1 - 4 | .1 - 4 | .1 - 4 |
Active Area Specifications
Code Number |
Active Area | Bias Voltage | Typical VW-1 | Package Size |
|
---|---|---|---|---|---|
Inches | mm | Typical | |||
1 | .040 | 1 | 50 | 1-4x104 | TO-5 & TO-46 |
2 | .080 | 2 | 100 | .5-2x104 | TO-5 |
3 | .120 | 3 | 150 | .4-1x104 | TO-5 |
5 | .200 | 5 | 250 | 3-6x103 | TO-8 |
10 | .400 | 10 | 500 | 600 | TO-3 |
Mechanical Specifications
TO-46 |
TO-5 |
TO-8 |
TO-3 |